Sirocco UPS

High Frequency 3-Phased Online Double Conversion Uninterruptible Power Supplies

This series UPS is a kind of three-in & out High Frequency )H.F) Online Double Conversion Uninterruptible Power Supply, it can solve most of the power supply problems, such as:

  • • blackout                                           
  •  •  over-voltage
  • • under-voltage                                 
  •   •  voltage sudden drop,
  • • oscillating of decreasing extent       
  •  •  high voltage pulse
  • • voltage fluctuation                          
  •   •  surge
  • • inrush current                                 
  •   • harmonic distortion (THD)
  • • noise interference                           
  •   • frequency fluctuation

This UPS can be applied to different applications from computer device, automatic equipment, communication system to industrial equipment.

  • • Online Double Conversion
  • • Output Transfer Time: 0ms
  • • PFC technology
  • • Full Digital Control (DSP)
  • • Output Power Factor: 0.9
  • • Input current harmonic: 3%
  • • ECO function
  • • Charging/ Rectifier/ Inverter fully digital controlled technology
  • • Optomization battery group. Bettery quantity: 16/ 20/ 32 or 60 units (optional)
  • • Wide Input Voltage Range: 208 - 478 Vac
  • • Wide Input Frequency Range: 46 - 66 Hz
  • • DC start
  • • Communication port: USB/ RS232/ RS485/ Parallel port/ Dry contact
  • • Options: SNMP card/ Relay card
  • • LCD & LED, double display
  • • Intelligent charging management
  • • EPO function
  • • Common battery group
  • • The output can meet 100% unbalanced load

Specifications

Use cases

  • Industry icon
  • Data center icon

This series UPS is a kind of three-in & out High Frequency )H.F) Online Double Conversion Uninterruptible Power Supply, it can solve most of the power supply problems, such as blackout, over-voltage, under-voltage, voltage sudden drop, oscillating of decreasing extent, high voltage pulse, voltage fluctuation, surge, inrush current, harmonic distortion (THD), noise interference, frequency fluctuation, etc..

This UPS can be applied to different applications from computer device, automatic equipment, communication system to industrial equipment.

Emergency Power Off (EPO)

The Emergency Power Off (EPO) button, also called an EPO switch or EPO panel, is a safety measure for quickly disconnecting electrical power to a particular piece of equipment, or to an entire facility, in the event of an emergency.

LCD/LED Display

With LCD plus LED displays, the user may easily get UPS status and its operational parameters, such as input/ output voltage, frequency & load%, battery % and ambient temperature, etc...

Charging Current can be reconfigured

Via setting tool, the user may set the capacity of the batteries as well as reasonable charging current and maximum charging current. Constant voltage mode, constant current mode or floating mode can be switched automatically and smoothly.

Intelligent Battery Charging Method

The series UPS adopts advanced three-stage charging method: 1st stage: High current constant current charging to guarantee to charge back to 90%. 2nd stage: Constant Voltage in order to vitalize battery and make sure batteries are fully charged. 3rd stage: Floating mode, with this 3-stage charging method, it extends the life of the batteries and guarantees fast charging.

Digital Control

This series UPS is controlled by Digital Signal Processor (DSP); ehance, it increases reliability, performance, self proteciton, self-diagnostics and so on.

Intelligent port slots

The use of the SNMP agent and relay card makes it easier in management features such as: • Setting up and programming  extinctions • Remotely control and monitor the UPS.

UPS monitoring & Automatic shutdown software

The software is compatible with Novell Netware, Windows 2000/XP/Vista/7, Windows server 2003/2008/2012, Linux, FreeBSD and Mac. Support SEC Protocol & USB Interface.

Battery Configuration

10-30 KVA: from 20 blocks to 60 blocks. The battery voltage of this UPS series can be configured at 16 blocks to 30 blocks or above according to your convenience. 40-60 KVA: from 32 blocks to 40 blocks. The battery voltage of this series UPS can be configured at 32 blocks, 34 blocks, 36 blocks, 38 blocks or 120 blocks according to your convenience.

Audible Alarm

Some of the common UPS statuses with respect to their buzzer beep descriptions occurs whenever there are: • Weak sector • Overload etc..

3 Phase In/3 Phase Out UPS

It is 3Phase In/3Phase Out high-density UPS system, of which input current is kept in balance without any unbalance problem to occur.

Views

Sirocco - Back

Sirocco - front

Products

POOIP1401 - Sirocco 10KVA TT with 20pcs 12V9AH batteries

  • Type1 : Online Double Conversion UPS
  • Type2 : T/ T
  • Voltage : 10Kva V
  • Power factor : 0.9
  • Bypass module : Automatic (in-built)
  • Number of batteries : 18-20 pcs
  • Output transfer time : 0 ms
  • Mode : ECO
  • Battery charge mode : Intelligent
  • Standards : IEC/EN62040-1,IEC/EN60950-1
  • Backup autonomy at full load : 10mins min
  • Noise level : ˂55 Db
  • Paralleling kit : Built-in UPS
  • Features:(surge protection/EMI filter for noise isolation/auto restart, cold start/auto shutdown/automatic frequency synchronization/Self-diagnosis function/surge protection) :
1 pcs / carton
45.00 kg
94.5 x 36.5 x 111.0 cm cm

POOIP1402 - Sirocco 20KVA TT with 40pcs 12V9AH batteries

  • Input rated voltage : 380/ 400/ 415 Vac
  • Input voltage range : 208 ~ 478 Vac
  • Input frequency range : 45-55Hz at 50Hz/54-66Hz at 60Hz (auto sensing) Hz
  • Input Power Factor : ≥0.99
  • Current THDI : ≤3%(100% non-linear load) %
  • Generator Input : Supported
  • Output rated voltage : 380/ 400/ 415 Vac
  • Output Power Factor : 0.9
  • Output voltage regulation : ±1 %
  • Output frequency utility mode : ±1%, ±2%, ±4%, ±5%, ±10% of the rated frequency
  • Output frequency battery mode : (50/ 60 ± 0.2%) Hz
  • Crest Factor : 3:1
  • Output THD : ≤2% with linear load
  • Output THD : ≤5% with non linear load
  • Battery voltage(Standard unit: ±120Vdc (2x20pcs 12V9AH); Long run unit Optional Voltage: ±96V/ ± 108V/±120Vdc (16/18/20 pcs optional)) : Refer to Annex_02(a)
  • Battery charge current : Standard unit: 2.7A/ Long run unit: Max.current 10 A
  • Back-up time : Up to 30 minutes of back-up autonomy at full load.
  • Transfer Time : Utility to Battery : 0ms; Utility to bypass: 0 ms
  • AC Mode overload protection(Load≤110%: last 60min,≤125%: last 10min,≤150%: last 1min, >150% change to bypass immediately) :
  • Bat. Mode overload protection(Load≤110%: last 10min, ≤125%: last 1min, ≤150%: last 5S, >150% shut down UPS immediately) :
  • Bypass Mode overload protection : Breaker 40 A
  • Short Circuit overlaod protection : 140 peak A
  • Overheat overload protection(Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately) :
  • Battery Low overlaod protection : Alarm and Switch off
  • Battery overload protection : Advanced Battery Management
  • Noise Suppression : Complies with EN62040-2
  • Audible & Visual alarms : Line Failure, Battery Low, Overload, System Fault
  • Status LED & LCD display(Line Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault) :
  • Reading On the LCD display(Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature) :
  • Technical specs : Refer to Annex_01(a) & (b)
  • Certifications(BS 5750-2:1987 replaced by EN 29002:1987,ISO 9002:1987 in 1994. See attached Annex_03(a)/ (b) & (c) for certifications) :
1 pcs / carton
199.00 kg
111.0 x 36.5 x 94.1 cm cm

POOIP1404 - Sirocco 30KVA TT with 60pcs 12V9AH batteries

  • Type1 : Online Double Conversion UPS
  • Type2 : T/ T
  • Voltage : 30Kva V
  • Power factor : 0.9
  • Bypass module : Automatic (in-built)
  • Number of batteries(12V9Ah) : 60pcs
  • Output transfer time : 0 ms
  • Mode : ECO
  • Backup autonomy at full load : 15-20 minutes at full load connected to the UPS
  • Noise level : ˂58 Db
  • Standards : IEC/EN62040-1,IEC/EN60950-1
  • Battery charge mode : Intelligent
  • Paralleling kit : Built-in UPS
  • Features:(surge protection/EMI filter for noise isolation/auto restart, cold start/auto shutdown/automatic frequency synchronization/Self-diagnosis function/surge protectio) :
  • Technical specifications : Refer to Annex_01
  • CE & EMC/ LVD Certifications : Refer to Annex_01(a), (b) and (c)
  • ISO Certificate : Refer to Annex_01(d)
1 pcs / carton
251.00 kg
111.0 x 36.5 x 94.1 cm cm

POOIP1403 - Sirocco 40KVA TT Longue autonomie sans cabine sans batteries (redondance incluse)

  • Type1(Model) : 40 KVA
  • Type2(Capacity) : 36 KW
  • Type3(Phase) : 380/ 400/ 415 Vac Vac
  • Type4(Voltage Range) : 208 ~ 478 Vac Vac
  • Type5(Frequency Range) : 45-55Hz at 50Hz/54-66Hz at 60Hz (auto sensing) Hz
  • Type6(Power factor) : 0.9
  • Type7(Current THDi) : ≤3%(100% nonlinear load) %
  • Type8(Max. voltage: 220Vac: +25%(optional +10%,+15%,+20% ) 230Vac: +20%(optional +10%,+15% ) 240Vac: +15%(optional +10% ) Min. voltage: -45% (optional -10%, -20%, -30%) Frequency protection range: ±10%) : Bypass voltage range
  • Type9(Generator Input) : Support
  • Type10(Output Voltage) : 380/400/415Vac Vac
  • Type11(Output power factor) : 0.9
  • Type12(Voltage Regulation) : ±1% %
  • Type 13(Transfer Time) : Utility to Battery : 0ms; Utility to bypass: 0ms ms
1 pcs / carton
83.00 kg
95.1 x 37.5 x 104.8 cm cm

SOIIP0301 - Cabine batteries sirocco sans batteries (max 80 pcs 7 ou 9 Ah)

1 pcs / carton
76.00 kg
95.1 x 37.5 x 104.8 cm cm

POOIP1405 - Sirocco 30KVA TT longue autonomie sans batteries

  • Type1 : Online Double Conversion UPS
  • Type2 : T/ T
  • Voltage : 30Kva
  • Power factor : 0.9
  • Bypass module : Automatic (in-built)
  • Output transfer time : 0 ms
  • Mode : ECO
  • Noise level : ˂58 Db
  • Standards : IEC/EN62040-1,IEC/EN60950-1
  • Battery charge mode : Intelligent
  • Paralleling kit : Built-in UPS
  • Features : (surge protection/EMI filter for noise isolation/a

POOIP1406 - Sirocco 10 KVA TT + SNMP + cable //


POOIP1407 - Sirocco 20 KVA TT + SNMP + cable //


POOIP1408 - Sirocco 30 KVA TT + SNMP + cable //


POOIP1409 - Sirocco 40 KVA with cabinet and 80 pcs 9Ah (~10 min@80% load)


Specifications

ModelSIROCCO 10 KVASIROCCO 20 KVASIROCCO 30 KVASIROCCO 40 KVA
Power9000(W)18000(W)27000(W)36000(W)
Input
Input Phase3 Phase 4 Wires and Ground
Input Rated Voltage380/ 400/ 415 Vac
Input Voltage Range208 ~ 478 Vac (AUTO-DETECT)
Input Frequency Range45 - 55 Hz at 50 Hz/ 54 - 66Hz at 60Hz (auto sensing)
Input Power Factor≥0.99
Bypass Voltage RangeMax voltage: 220 Vac: + 25 % (optional + 10 %, + 15 %, + 20% )
230Vac: +20%(optional +10%,+15% )
240Vac: +15%(optional +10% )
Min voltage: - 45 % (optional – 10 %, - 20 %, - 30 %)
Frequency protection range: ±10%
Current THDI≤ 3% (100 % nonlinear load)
Generator inputSUPPORTED
Output
Output Phase3 Phase 4 Wires and Ground
Output Rated Voltage380/ 400/ 415 Vac
Output Power Factor0.9
Output Voltage Regulation±1%
Output FrequencyUtility mode: ±1%, ±2%, ±4%, ±5%, ±10% of the rated frequency(optional)
Battery mode: (50/ 60 ± 0.2%) Hz
CREST Factor3:1
THD≤ 2 % with linear load
≤5% with non linear load
Batteries
Battery Voltage240VDC480VDC720VDC960VDC
Functions
Transfer Time0 ms
Charging Current1 à 4 A
Overload Protection AC ModeLoad ≤ 110%: last 60min,≤125%: last 10min,≤150%: last 1min, >150% change to bypass immediately.
Overload Protection BYPASS Mode20 A Breaker40A Breaker63A Breaker80A Breaker
Overload Protection BATT ModeLoad ≤ 110%: last 10min, ≤125%: last 1min, ≤150%: last 5S, >150% shut down UPS immediately
Short Circuit120A peak 164A Peak (adjustable) 
OverheatLine Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately
Low BatteriesAlarm and Switch off
Self DiagnosticUpon Power On and Software Control
EPO (optional)Shut down UPS immediately
BatteryAdvanced Battery Management
Noise SuppressionComplies with EN62040-2
Audible & Visual AlarmsLine Failure, Battery Low, Overload, System Fault
Status LED & lCD DispalyLine Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault   
Commmunication InterfaceUSB, RS485, Parallel (optional), Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional)
Reading on the LCDInput Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature
Operating Temperature0°C~40°C
Storage Temperature-25°C~55°C
Humidity0~95% non condensing
Altitude< 1500m.When>1500m,lower the rated power for use
Safety ConformanceCE,EN/IEC 62040-2,EN/IEC 62040-1-1